Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
research:electromagnetic_sensors_measurments [2016/10/27 16:46] – created mrkvaresearch:electromagnetic_sensors_measurments [2016/10/27 17:19] (current) mrkva
Line 1: Line 1:
 ====== Electromagnetic sensors measurements ====== ====== Electromagnetic sensors measurements ======
  
-Recording device: Olympus LS-11 (Gain: 10, High sensitivity)+**Measurement conditions**\\ 
 +EM source: white noise player through speaker\\ 
 +Measurement device position: 4 cm from the speaker coil\\ 
 +Recording device: Olympus LS-11 (Gain: 10, High sensitivity)\\ 
 +FFT plot: 65536 window size, Blackman-Harris
  
-Conditions: +**Generic eBay coil**\\ 
-white noise +Peak Amplitude: -11,25 dB\\ 
-- measurement position4 cm from the speaker coil+Total RMS Amplitude-22,93 db\\
  
-Generic eBay coil: +**Japanese vintage coil**\\ 
-Peak Amplitude: -11,25 dB +Peak Amplitude: -10,46 dB\\ 
-Total RMS Amplitude: -22,93 db+Total RMS Amplitude: -22,84 db\\
  
-Japanese vintage coil: +**Elektrouši**\\ 
-Peak Amplitude: -10,46 dB +Peak Amplitude: -6,34 dB\\ 
-Total RMS Amplitude: -22,84 db+Total RMS Amplitude: -17,64 db\\
  
-Elektrouši: +**Elektrouši Pro**\\ 
-Peak Amplitude: -6,34 dB +Peak Amplitude: -2,52 dB\\ 
-Total RMS Amplitude: -17,64 db +Total RMS Amplitude: -13,26 db\\
- +
-Elektrouši Pro: +
-Peak Amplitude: -2,52 dB +
-Total RMS Amplitude: -13,26 db+